Calem Blogs

Blogs of CalemEAM

Parameterizing Weight Scaling for Auto Min/Max Processes

The min/max weight scaling can be parameterized based on unit price, new min and max stock levels in the coming release of R2025e (July 2025).

  • A rule for weight scaling can be scoped for min level only, max level only, or both.
  • A rule may be parameterized by unit price, new min level, and new max level.
  • A sequence is used to determine the order to execute rules with a default value of 100.
  • Rules of smaller sequences take precedence over rules of greater sequences.
  • For instance, the screenshot below shows three rules for min/max weight scaling for inventory without ABC classification based on usage.
    • The new min level will be scaled to 20% (or 0.2) of its calculated value when unit price is less than (<) 1000 and the new calculated min level is greater than (>) 4. Sequence is 90.
    • The new max level will be scaled to 50% (or 0.5) of its calculated value when unit price is less than (<) 1000 and the new calculated max level is greater than (>) 6Sequence is 90.
    • Otherwise, both new min and max levels are scaled to 60% of calculated values. Sequence is 100. 
  • See this blog for weight scaling before rules are introduced.
  • See this blog for auto min/max processes in Calem.
Visualizing Asset Outages on the Map

Related Posts